Add RPS Records in Bulk

This topic describes how to add RPS records to Milesight Development Platform in bulk.

Prerequisites

  • You have collect the devices' SNs or EUIs.
  • You have upgraded the firmware version of device model to a supported version (except for LoRaWAN® end devices).
  • If you have a large number of devices that need to be added, it's recommended to compile the devices' SNs or EUIs into a file with the following requirements:
    • Format: xlsx, xls, or txt.
    • Size: Less than 100 KB.
    • Content: For xlsx or xls files, each line contains information of one device, with two columns from left to right showing SN (or EUI) and RPS record name; for txt files, each line contains information for one device, with SN(or EUI) and device name from left to right and separated by ';'.

  • If you want to apply custom settings to devices, you need to create custom Config templates for the devices.
  • If you want to apply custom settings to devices with your server, arrange an RPS server with an accessible URL that stores and manages the configuration files.

Procedure

  1. Log in to Milesight Development Platform.
  2. On the top bar, select the RPS tab.

  3. Click Batch Add.
  4. In the Batch Add page, choose one of the following methods to fill in the devices' SNs or EUIs.
    • If you have compile the devices' SNs or EUIs into an xlsx, xls, or txt file, then click Upload to upload the file.

    • If not, do as follow:

      or

      1. In the SN/DevEUI section, enter the SNs or EUIs of the desired devices, with each SN or EUI on a separate line. If you require to add RPS record name, please add the SN(or EUI) and device name from left to right and separated by ';' on each line.
      2. Click Add to Device List.
    If the SNs or EUIs are correct, the system will automatically display the device information in the Device List section.
  5. In the Device List section, edit the device name.

  6. In the RPS Status section, add the configuration to apply to the devices.

    1. Select the configuration type.
    2. Add the configuration file or URL as required.
      • Configuration File: In the Configuration File drop-down list, select the desired configuration file created from Milesight Development Platform. You can click Custom to edit the selected file as needed.
        Note: The listed files include the default Config template and the custom Config templates you created.
      • Configuration URL: Fill in the URL to apply to the configuration file. The URL can be generated by below methods:
        1. Copy the URL of custom template from Milesight Development Platform.
        2. Download the config template or customize your config template file, and put it to your custom configuration server URL.
  7. Click Save.

Result

The RPS records of the devices are added to Milesight Development Platform. When the devices have accessed the Internet after initial boot-up or reset to factory default, they will apply for the RPS configuration from Milesight Development Platform or your custom configuration URL.

If the devices are managed by Milesight Development Platform, the RPS statuses will change to Activate.